HG Series Touch Screen Gloss Meter HNG268
HNG series economic gloss meter is independently developed by 3nh, with independent intellectual property. Manufactured according to International standard ISO2813and Chinesestandard GB/T 9754,it is the world's first full large touch screen gloss meter. With GQC6 PC software, gloss measurement is more convenient to use. Stable performance and high accuracy measurement makes it very popular all over the world.
Key Highlights
Large Touch Screen Operation, Fully Automatic Calibration
Tri-Angle 20°, 60°, 85° Test
Display 5 sets of measurement data
Basic measurement, statistical measurement, continuous measurement, QC measurement
One button for all angles measurement at the same location
Input gloss value manually
NHG268 gloss meter features with 20, 60 and 85° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with the standards of ASTM D523, ASTM D2457. NHG268 conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source.
NHG268 gloss meter can test material with high gloss (0-2000Gu), and universally apply to paint, ink, stoving varnish, coating, wood products; marble, granite, vitrified polished tile, pottery brick and porcelain; plastic, paper; hardware industries, etc. for gloss measurement and gloss data transmission.
NHG268 Multi-angle Precise Gloss Meter | |
Model: | NHG268 |
Measuring Angle |
20°/60°/85° Comply with standard ISO 2813, GB/T 9754, ASTM D 523, ASTM D 2457 |
Measuring Area (mm) | 20°: 10x10 60°: 9x15 85°: 5x36 |
Measuring Range | 20°:0~2000GU 60°:0~1000GU 85°:0~160GU |
Division Value | 0.1GU |
Measurement Range Repeatability Reproducibility |
0-10GU 10-100GU 100-2000GU ± 0.1GU ± 0.2GU ± 0.2%GU ± 0.2GU ± 0.5GU ± 0.5%GU |
Measurement Standard | Conform with JJG696 first class glossmeter working requirement |
Chromaticity Corresponding | Corresponding with CIE 1931(2°) under CIE C light source |
Errors | ±1.2 , ± 1.2% |
Measuring Time | 1.0s |
Dimension | L*W*H : 160mm*75mm*90mm |
Weight | 350g |
Language | Chinese/English |
Battery | 3.7V,3200mAh Li-ion Battery ,>10000 times(within 8 hours) |
Display | TFT 3.5 inch, capacitive touch screen |
Interface | USB/RS-232 |
Storage | Basic mode: 1000; Statistical Mode: 5000,Continuous mode : 5000 |
Software | GQC6 Quality Control Software with QC report printing functions and more extended functions. |
Operation Temperature | 0~40℃(32~104°F) |
Storage Temperature | -20~50℃(-4~122°F) |
Humidity | <85% relative humidity, no condensation |
Standard Accessories | Power Adapter, USB cable, User Manual, CD (Including QC software), Calibration Plate |
Optional Accessories | Miniature Printer |
Note | The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Gloss meter
At most of time, we have stock in the factory. Generally it is 1-3 working days after the payment confirmed. After shipped, we will email you the tracking number. You can check the shipping status of your order on the website. If you are in urgent need, we can consider making special arrangement for you.
Threenh Technology colorimeters provide a color deviation prompt function according to the Lab value, which can provide a reference for color matching. The handheld colorimeter can only indicate blacker, whiter, redder, greener, yellower or bluer, but it cannot provide accurate color formulas. Only with the help of a spectrophotometer and professional color matching software can fully realized automated color matching.
Who are we? Threnh Technology: 22-Year Professional Color Measurement Solution Provider
Threnh Technology is a Chinese professional Measurement Instrument manufacturer with 22 years of industry experience, specializing in the field of color measurement and surface gloss detection. Integrating research and development, design, production, marketing, and sales, the company takes technological innovation as its core and is committed to providing global customers with high-precision and intelligent testing instruments as well as professional solutions.
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.
You can choose a colorimters depending on the substrate you are measuring the color of, whether it is opaque, translucent or transparent. In short, you can consider the following factors for choosing the right 3NH colorimeter for your needs: Sample Opacity, Physical Form, Optical Properties needed, Measurement Methods required, Scales and Indices needed, Instrument Standards Conformance (ASTM/ISO/Other), Instrument Geometry, Instrument Performance, Location (laboratory, portability, in-process) and Sample Handling requirements.
By systematically addressing these factors, you can select a colorimeter that optimizes accuracy, efficiency, and value for your specific application.Learn more from our ultimate guide on colorimeter selection. If unsure, consult the 3NH manufacturer for personalized recommendations based on your sample and workflow.