In line with Chinese Grade 1 Spectrodensitometer standard
3nh YD5050 Plus Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control
Key Highlights
45/0 geometrical optics structure, comply with CIE
Reflectance spectrum, CMYK density and Lab
3.5-inch TFT true-color screen, capacitive touch screen, concave grating
Ergonomic structure design
Φ2/4/8mm Optional apertures
Pinting plants process control and quality control
3nh launched new model YD5050 Plus Grating Spectrophotometer Densitometer with 45/0(45 ring-shaped illumination, 0 degree viewing angle), comply to standard ISO 5-4,CIE No.15. It is suitable for using in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing.
Under the 45/0 geometric optical illumination and the testing conditions of M O, M 1,M 2 , M 3 stipulated by ISO 13655 standard, the instrument can accurately measure the reflectance data of samples. Under multiple color spaces, it can accurately measure various printing density indexes, color difference formulas and color indexes, and can meet the user's regular testing of various parameters.
Product Features
1. 45/0 geometrical optics structure, comply with CIE, the testing conditions of M O, M 1,M 2 , M 3 stipulated by ISO 13655 standard, it can accurately measure various printing density , overprint rate and other printing parameters.
2. Accurately measure reflectance spectrum, CMYK density and Lab value of the sample;
3. High-configuration electronic hardware: 3.5-inch TFT true-color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS image sensor, etc.;
4. Perfect combination of the beautiful appearance and the ergonomic structure design;
5. Optional apertures: Φ2/4/8mm, adapt to more samples;
6. Large-capacity storage space, over 20,000 test data
7. Combined LED light sources with long life and low power consumption, including UV light;
8. USB/Blue2.1 dual communication mode is widely useful;
9. Especially suitable for process control and quality control of printing plants;
10. PC software has powerful function expansion.
Model | YD5050 Plus |
Measurement Geometry | 45/0(45 ring-shaped illumination, 0 degree viewing angle); ISO 5-4,CIE No.15 |
Features | high accuracy spectrophotometer densitometer, apply in ink printing, in Film Processing, Textile Printing and Dyeing, Plastic Electronics and Other Industries for Color Measurement and Quality Control;especially suitable for the measurement and quality control of optical density and dot enlargement in ink printing;able to customize single aperture Φ2mm,Φ4mm,Φ8mm. |
Light Source | Combined LED Light, UV Light |
Spectral separation device | Concave Grating |
Detector | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400~700nm |
Wavelength Pitch | 10nm |
Half Bandwidth | 10nm |
Measurement Conditions |
Compliance with ISO 13655 measurement conditions; M0 (CIE Light Soure A) M1 (CIE Light Soure D50) M2 (Excluding UV light source) M3 (M2+Polarized light filter) |
Density Standards | ISO Status A, E, I, T |
Density index | Density value, density difference, dot area, dot enlargement, overprint, printing characteristics, printing contrast, tone error and gray scale, density scanning |
Measurement aperture | Customized one aperture:Φ2mm,Φ4mm,Φ8mm optional |
Color Spaces | CIE LAB,XYZ,Yxy,LCh,CIE LUV,HunterLAB |
Color Difference Formula | ΔE*ab,ΔE*94,ΔE*00,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE(Hunter) |
Other Colorimetric Index |
WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313), MI (Metamerism Index),Opacity, |
Observer Angle | 2°/10° |
Illuminants | A,C,D50,D55,D65,D75,F2(CWF),F7(DLP),F11(TL84),F12(TL83/U30),F1,F3,F4,F5,F6,F8,F9,F10(TPL5) |
Measurement Time | About 1.5s |
Repeatability | Density: Within 0.01 D |
Chromaticity value:within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Except M3 | |
Inter-instrument Error | Within ΔE*ab 0.18 (Average for 12 BCRA Series II color tiles) Except M3 |
Measurement mode | Single Measurement, Average Measurement(2-99) |
Size(L*W*H) | 184*77*105mm |
Weight | About 600g |
Power source | Li-ion battery. 5000 measurements within 8 hours |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Interface | USB, Bluetooth ®5.0 |
Data memory | 20000 pcs |
Language | Simplified Chinese, English, Traditional Chinese |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation);altitude: less than 2000 m |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, USB Cable, Built-in li-ion battery, User Manual, software(download from the website),White and Black Calibration Board, Protective Cover,Polarization filter box,Locating Plate |
Optional Accessory | Micro Printer |
Notes: The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrodensitometer
The Ideal Accurate and User - Friendly Spectrophotometer for Your Needs
This Spectrophotometer device measures the reflectivity,absorbance, transmittance, and fluorescence of light passing through samples, providing invaluable data for a wide range of applications, provide unrivaled accuracy for reliable results.
Selecting an appropriate spectrophotometer offers significant advantages for precision color analysis and quality control. When choosing an accurate and user - friendly spectrophotometer, consider factors such as wavelength range, sensitivity, sample handling options, and available software features. By investing in the right spectrophotometer, you can streamline your analytical processes, obtain more accurate results, and enhance the overall efficiency of your laboratory or industrial operations.
Choosing the right model—whether portable, benchtop, or inline—aligns technology with specific industry needs, ensuring long-term reliability and optimized color management.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
Now our testing machines have been sold to more than 80 countries, like USA, Canada, Russia,UK, Italy, Germany, European , India, Pakistan, Philippine, Singapore, Malaysia,Thailand , Vietnam, Korea,Saudi Arabia,Brazil...and so on. We sell to the global market.
With centers in 20 countries, including India, Japan, USA, Germany, Singapore, China, South Korea, and Taiwan, Threenh Technology’ s service network aims to provide customers with convenient access to service globally. With over 1 million measuring instruments sold, our expertise is our greatest asset, enabling us to work with our customers on solutions to complex measurement challenges.
A colorimeter is a scientific instrument used to measure and analyze the color characteristics of objects or materials. It quantifies color by evaluating specific parameters related to human visual perception and standardized color spaces.
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.